Lay-Z-Spa Temperature Sensor\n\nE03 - E04 - E05\n\nOEM Part - Tested & Ready for Installation\n\nCommon Problems\n\nFailure typically presents as a persistent E03, E04, or E05 fault code that does not clear after reset.\n\n--E03 should only be triggered when the water temperature falls below 4\u00B0C (39\u00B0F).\n\n--E04 should only occur when the water temperature exceeds 40\u00B0C (104\u00B0F).\n\n--E05 indicates that the pump\u2019s logic controller is unable to detect the temperature sensor, or that the sensor reading is significantly outside the expected operating range. This can be caused by a faulty sensor or logic controller.\n\nIf an E04 error temporarily clears but reappears after a short period of operation, this commonly indicates restricted water flow causing localised overheating within the heater assembly. The most frequent causes are a blocked filter cartridge, or limescale accumulation within the heater matrix reducing flow efficiency and increasing heat transfd