Aluminium PTC Heating Element - AC220-240V 2000W\n\nS100102 - Bestway Lay-Z-Spa AirJet Pumps\n\nRefurbished, Fully Tested & Ready for Installation\n\nCommon Problems\n\nPower tripping when the heater is enabled? Typically indicates an element fault to ground or a dead short, causing the PRCD / GFCI or house breaker to activate for safety.\n\nLeaking from the assembly? Commonly caused by perished or chemically degraded seals, especially when exposed to chlorinated water over long periods.\n\nGrey Blue Grit deposits? This is typically caused by a combination of limescale and copper sulphate based algicide having a galvanic reaction with the aluminium heater. Heaters showing this level of degradation should be replaced. To prevent this from reoccurring, we would recommend managing the use of algicide, changing the spa water every 8-12 weeks and routine descaling of the pump. Suitable descaling attachments and service components are available in our other listings.\n\nSlow or No Heatd